stal
Gutter system

Galeco STAL

A deeply thought out,
deep gutter
 

Galeco STAL system is made of the best quality coated steel. It is provided with four protective layers: zinc, passivation coat, primer, and organic coat. It is the only TOTAL PROTECTIVE SYSTEM FOR GUTTERS AND FALL PIPES as foiling and pipe internal seam guarantee high aesthetics quality without any scratches.

Materials

Galeco STAL System is made of high-quality coated steel. High durability of plates is ensured through the application of additional 4 protective layers which prevent the material against adverse weather conditions. Steel core thickness is 0.6 mm. It is double, zinc-coated, passivated, and coated with organic protective aesthetic layer.

Colour scheme

 

STAL

gutter type / pipe diameter
Colour RAL 120/90 135/90 135/100 150/100 150/120
Graphite
RAL 7015
         
Brick
RAL 8004
         
Dark brown
RAL 8019
         
Chocolate brown
RAL 8017
         
White
RAL 9003
         
Black
RAL 9005
         
Dark red
RAL 3009
         

STAL SATIN

gutter type / pipe diameter
Colour RAL 120/90 135/90 135/100 150/100 150/120
Graphite SATIN
RAL 7016
         
Black SATIN
RAL 9005
         
Chocolate brown SATIN
RAL 8017
         

STAL METALIC

gutter type / pipe diameter
Colour RAL 120/90 135/90 135/100 150/100 150/120
Copper
RAL 8007
         
Antracyt
RAL 9007
         
Silver
RAL 9006
         

Efficiency table

Following table determines Galeco STAL system efficiency in accordance with the placement of the fall pipe.

gutter type / pipe diameter
Positions of the downpipe 120/90 135/90 135/100 150/100 150/120

60 m2

110 m2

110 m2

150 m2

150 m2

120 m2

220 m2

220 m2

300 m2

300 m2

Standards

Polska Norma PN-EN 612  for gutters, pipes and profiles - May 2006, „Roof gutters made of metal sheets with round reinforced front side rim and overlapped fall pipes”.

Polska Norma PN-EN 1462 - April 2006, „Handles for roof gutters. Requirements and examinations”.

Our own declarations have been confirmed through testing that were carried out by Building Research Institute: testing reports no.:
LOW/019.1/2007, LOW/019.2/2007, LOW/108.1/2008, LOW-537.1/2009.

Corrosion Classes

Class Corrosion Enviroment description
C1 VERY LOW Heated locations with dry air and insignificant pollution level, e.g. offices, schools and hotels.
C2 LOW

Locations with low air pollution level. Non-heated locations with temperature and humidity fluctuations characterised by low frequency condensation and low level of air pollution, e.g. fitness centres, warehouses.

C3 MODERATE

Locations in which salt or air pollutions are present at a moderate level. Urban locations, light industry zones and areas that are subject to a certain impact from the waterside. These are locations with moderate humidity and those in which some air pollutants are present such as digester houses, creameries, laundries, etc.

C4 HIGH

Locations in which salt or air pollutions are present at a moderate level. Industrial and waterside areas. Locations with air high humidity and high pollution originating from industrial processes, e.g. chemical industry, indoor swimming pools, shipyards.